7710
Series - Stainless Steel
This
all 316L stainless steel meter utilizes a float and tapered tube (rotameter)
design which offers longer, more linear scales,
better pointer
stability and 40% greater accuracy than competitively priced products.
A 4-20mA transmitter option adds to its versatility.
Mounting
Bracket A
mounting bracket is available for 7700 Series meters, order numbers 706 thru 714.
This 304 Stainless Steel bracket can greatly reduce installation
time. Please call the factory for details about this low
cost option.
Specifications
Dimensions
(Inches)
Order
Number
Full Scale
Flow-Water
Dimensions (Inches)
With FNPT Connections
150 # Flange
300 # Flange
FNPT
A
B
C
D
E
F
G
H
G
H
706
33.0 GPH - 1/2" FNPT
0.5
1.312
11
5.125
5
3.375
4.625
3.5
13.125
3.75
13.625
708
1.1 GPM - 1/2" FNPT
0.5
1.312
11
5.125
5
3.375
4.625
3.5
13.125
3.75
13.625
710
2.0 GPM - 1/2" FNPT
0.5
1.312
11
5.125
5
3.375
4.625
3.5
13.125
3.75
13.625
712
4.0 GPM - 1/2" FNPT
0.5
1.312
11
5.125
5
3.375
4.625
3.5
13.125
3.75
13.625
714
6.0 GPM - 1/2" FNPT
0.5
1.312
11
5.125
5
3.375
4.625
3.5
13.125
3.75
13.625
716
5.0 GPM - 1" FNPT
1
1.875
13.25
5.25
5
4
4.625
4.25
16.75
4.88
17.5
718
10.0 GPM - 1" FNPT
1
1.875
13.25
5.25
5
4
4.625
4.25
16.75
4.88
17.5
720
16.5 GPM - 1" FNPT
1
1.875
13.25
5.25
5
4
4.625
4.25
16.75
4.88
17.5
722
25.0 GPM - 1" FNPT
1
1.875
13.25
5.25
5
4
4.625
4.25
16.75
4.88
17.5
724
35.0 GPM - 1 1/2" FNPT
1.5
2.375
13.875
5.625
5
4.5
4.625
5
18.625
6.12
19.25
726
60.0 GPM - 1 1/2" FNPT
1.5
2.375
13.875
5.625
5
4.5
4.625
5
18.625
6.12
19.25
728
76.0 GPM - 2" FNPT
2
3.5
13.875
6.75
5
5.625
4.625
6
17.156
6.5
17.75
730
100.0 GPM - 2" FNPT
2
3.5
13.875
6.75
5
5.625
4.625
6
17.156
6.5
17.75
732
120.0 GPM - 2" FNPT
2
3.5
13.875
6.75
5
5.625
4.625
6
17.156
6.5
17.75
734
152.0 GPM - 2" FNPT
2
3.5
13.875
6.75
5
5.625
4.625
6
17.156
6.5
17.75
736
150.0 GPM - 3" Flange
7.5
17.867
8.25
18.187
738
225.0 GPM - 3" Flange
7.5
17.867
8.25
18.187
740
300.0 GPM - 4" Flange
9
18.562
10
19.75
742
375.0 GPM - 4" Flange
9
18.562
10
19.75
744
450.0 GPM - 4" Flange
9
18.562
10
19.75
Dimensions (Inches)
With FLANGE Connections
Order
Number
Full Scale
Dimensions (Inches)
With NPT Connections
ANSI Class 150 #
ANSI Class 300 #
Flow-Air
FNPT
A
B
C
D
E
F
G
H
I
J
707
4.0 SCFM - 1/2" FNPT
0.5
1.312
11
5.125
5
3.375
4.625
3.5
13.125
3.75
13.625
709
8.0 SCFM - 1/2" FNPT
0.5
1.312
11
5.125
5
3.375
4.625
3.5
13.125
3.75
13.625
711
16.5 SCFM - 1/2" FNPT
0.5
1.312
11
5.125
5
3.375
4.625
3.5
13.125
3.75
13.625
713
24 SCFM - 1/2" FNPT
0.5
1.312
11
5.125
5
3.375
4.625
3.5
13.125
3.75
13.625
715
20 SCFM - 1" FNPT
1
1.875
13.25
5.25
5
4
4.625
4.25
16.75
4.88
17.5
717
42 SCFM - 1" FNPT
1
1.875
13.25
5.25
5
4
4.625
4.25
16.75
4.88
17.5
719
76 SCFM - 1" FNPT
1
1.875
13.25
5.25
5
4
4.625
4.25
16.75
4.88
17.5
721
100 SCFM - 1" FNPT
1
1.875
13.25
5.25
5
4
4.625
4.25
16.75
4.88
17.5
Alarm Options:
Inductive Slot Sensor Like inductive ring sensors, slot sensors are 2-wire, DC, low-current devices and are designed to be used with a remote intrinsic safety barrier/switch isolator. Single or dual slot sensors are available for the 7700 Series.
Sensor Specifications Power Supply: 5-25 VDC
(from Switch Isolator)
Max Current, Target Present: 1 mA
Max Current, Target Absent: 15 mA
Temperature Limits: -14°F to +212°F
Output: NAMUR
Repeatability: 0.01 mm
Switching Frequency: 2 kHz
Sensor Approvals*:
UL Listed: General Purpose
FM Approved: Intrinsically Safe*
CSA Certified: Intrinsically Safe*
Cenelec: Intrinsically Safe*
Power Supply: 12 to 33 Vdc
Maximum Current Consump.: 40 mA
Temperature Limits: -13° F to 158° F (-25 to 70° C)
Output: 4 to 20 mAdc
Accuracy: <0.5%
Linearity: +0.4%
Influence from bearing play: ±0.1%
Temperature influence (amb): 0.03% per °C
Power supply influence: ±0.1%
Load resistance influence: ±0.1% at R max.
*Specifications shown here are for the transmitter only and should not be confused with the actual performance capabilities of the flowmeter.
Ordering:
Use
the following guide to determine the specific product number
you require.